IFM SM8001 Magnetic Inductive Flow Meter
IFM SM8001 Magnetic Inductive Flow MeterIFM SM8001 Magnetic Inductive Flow MeterIFM SM8001 Magnetic Inductive Flow MeterIFM SM8001 Magnetic Inductive Flow MeterIFM SM8001 Magnetic Inductive Flow MeterIFM SM8001 Magnetic Inductive Flow Meter

IFM SM8001 Magnetic Inductive Flow Meter

Current Price: $142.49
  • Used IFM SM8001 Magnetic Inductive Flow Meter
  • Number of digital outputs: 2
  • Number of analog outputs: 1
  • Measuring range 6...1584 gph, 0.1...26.4 gpm
  • threaded connection G 1 DN25 flat seal
  • gold-plated contacts
  • Totalizer function; for industrial applications
  • Installation connection to pipe by means of an adapter
  • For Conductive liquids; water; water-based media
  • with conductivity: = 20 µS/cm
  • viscosity: < 70 mm²/s (40 °C)
  • Medium temperature [°F] 14...158
  • Pressure rating [bar] 16
  • Pressure rating [psi] 232
  • MAWP (for applications according to CRN) [bar] 11.2
  • Operating voltage [V] 18...30 DC; (to SELV/PELV)
  • Current consumption [mA] 95; (24 V)
  • Protection class III
  • Reverse polarity protection yes
  • Power-on delay time [s] 5
  • Number of digital outputs: 2
  • Number of analog outputs: 1
  • counter reset
  • Total number of outputs 2
  • Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
  • Electrical design PNP/NPN
  • Number of digital outputs 2
  • Output function normally open / closed; (configurable)
  • Max. voltage drop switching output DC [V] 2
  • Permanent current rating of switching output DC [mA] 200
  • Number of analog outputs 1
  • Analog current output [mA] 4...20; (scalable)
  • Max. load [O] 500
  • Analog voltage output [V] 0...10; (scalable)
  • Min. load resistance [O] 2000
  • Pulse output flow rate meter
  • Short-circuit protection yes
  • Type of short-circuit protection yes (non-latching)
  • Overload protection yes
  •  
  • Measuring range 6...1584 gph, 0.1...26.4 gpm
  • Display range -1902...1902 gph, -31.7...31.7 gpm
  • Resolution 2 gph, 0.05 gpm
  • Set point SP 14...1586 gph, 0.25...26.4 gpm
  • Reset point rP 6...1578 gph, 0.1...26.25 gpm
  • Analog start point ASP 0...1272 gph, 0...21.2 gpm
  • Analog end point AEP 312...1586 gph, 5.2...26.4 gpm
  • In steps of 2 gph, 0.05 gpm
  • Volumetric flow quantity monitoring
  • Pulse value 0.01...100 000 000 gal
  • Pulse length [s] 0,0025...2
  •  
  • Measuring range [°F] -4...176
  • Resolution [°F] 0.5
  • Set point SP [°F] -2.5...176
  • Reset point rP [°F] -3.5...175
  • Analog start point [°F] -4...140.5
  • Analog end point [°F] 31.5...176
  • In steps of [°F] 0.5
  •  
  • Flow monitoring Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW)
  • Repeatability ± 0,2% MEW
  • Temperature monitoring Accuracy [K]+_ 2,5 (Q > 0,26 gpm)
  •  
  • Flow monitoring Response time [s] 0.15; (dAP = 0, T19)
  • Delay time programmable dS, dr [s] 0...50
  • Damping process value dAP [s] 0...5
  •  
  • Temperature monitoring
  • Dynamic response T05 / T09 [s] T09 = 20 (Q > 0,26 gpm)
  • Software / programming
  • Parameter setting options- Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
  • Interfaces
  • Communication interface IO-Link
  • Transmission type COM2 (38,4 kBaud)
Details
  • Brand: IFM
  • Size: Length: 5 in. Width: 3 in. Height: 3 in.
  • Condition: Used
  • SKU: 208836
  • Consigner: J
  • Warehouse Storage Location: T-084
  • Shipping Weight (lbs, oz): 1,4
  • Lister: mc
  • Country of Manufacture: United States
  • Items in Lot: 1
  • Used IFM SM8001 Magnetic Inductive Flow Meter
  • Number of digital outputs: 2
  • Number of analog outputs: 1
  • Measuring range 6...1584 gph, 0.1...26.4 gpm
  • threaded connection G 1 DN25 flat seal
  • gold-plated contacts
  • Totalizer function; for industrial applications
  • Installation connection to pipe by means of an adapter
  • For Conductive liquids; water; water-based media
  • with conductivity: = 20 µS/cm
  • viscosity: < 70 mm²/s (40 °C)
  • Medium temperature [°F] 14...158
  • Pressure rating [bar] 16
  • Pressure rating [psi] 232
  • MAWP (for applications according to CRN) [bar] 11.2
  • Operating voltage [V] 18...30 DC; (to SELV/PELV)
  • Current consumption [mA] 95; (24 V)
  • Protection class III
  • Reverse polarity protection yes
  • Power-on delay time [s] 5
  • Number of digital outputs: 2
  • Number of analog outputs: 1
  • counter reset
  • Total number of outputs 2
  • Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
  • Electrical design PNP/NPN
  • Number of digital outputs 2
  • Output function normally open / closed; (configurable)
  • Max. voltage drop switching output DC [V] 2
  • Permanent current rating of switching output DC [mA] 200
  • Number of analog outputs 1
  • Analog current output [mA] 4...20; (scalable)
  • Max. load [O] 500
  • Analog voltage output [V] 0...10; (scalable)
  • Min. load resistance [O] 2000
  • Pulse output flow rate meter
  • Short-circuit protection yes
  • Type of short-circuit protection yes (non-latching)
  • Overload protection yes
  •  
  • Measuring range 6...1584 gph, 0.1...26.4 gpm
  • Display range -1902...1902 gph, -31.7...31.7 gpm
  • Resolution 2 gph, 0.05 gpm
  • Set point SP 14...1586 gph, 0.25...26.4 gpm
  • Reset point rP 6...1578 gph, 0.1...26.25 gpm
  • Analog start point ASP 0...1272 gph, 0...21.2 gpm
  • Analog end point AEP 312...1586 gph, 5.2...26.4 gpm
  • In steps of 2 gph, 0.05 gpm
  • Volumetric flow quantity monitoring
  • Pulse value 0.01...100 000 000 gal
  • Pulse length [s] 0,0025...2
  •  
  • Measuring range [°F] -4...176
  • Resolution [°F] 0.5
  • Set point SP [°F] -2.5...176
  • Reset point rP [°F] -3.5...175
  • Analog start point [°F] -4...140.5
  • Analog end point [°F] 31.5...176
  • In steps of [°F] 0.5
  •  
  • Flow monitoring Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW)
  • Repeatability ± 0,2% MEW
  • Temperature monitoring Accuracy [K]+_ 2,5 (Q > 0,26 gpm)
  •  
  • Flow monitoring Response time [s] 0.15; (dAP = 0, T19)
  • Delay time programmable dS, dr [s] 0...50
  • Damping process value dAP [s] 0...5
  •  
  • Temperature monitoring
  • Dynamic response T05 / T09 [s] T09 = 20 (Q > 0,26 gpm)
  • Software / programming
  • Parameter setting options- Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
  • Interfaces
  • Communication interface IO-Link
  • Transmission type COM2 (38,4 kBaud)